Skip to Content

Minor amenity features eligible for validation

External mesh fence or metal railing

The technical specifications of the external mesh fence or metal railing for validation and corresponding minor works items are listed in Part 4 of Schedule 3 of the Building (Minor Works) Regulation (B(MW)R). The works must be in existence or completed before 1 September 2020.

External mesh fence or metal railing on-grade

The prescribed building or building works item

8

The prescribed building or building works items 8

Corresponding minor works item

2.7

  1. Height of the structure, including any feature at its top
    ≤ 5m
  2. If the lower part of the structure is a solid fence wall, the height of the wall alone
    ≤ 2.5m
  3. Not used as a protective barrier

External mesh fence or metal railing on a roof

The prescribed building or building works item

9

The prescribed building or building works items 9
The prescribed building or building works items 9

Corresponding minor works items

2.56

  1. Height of the structure, including any feature at its top
    ≤ 2.5m
  2. If the lower part of the structure is a solid fence wall,
    • Height of the wall alone
      ≤ 1.1m
    • Thickness of the wall
      ≤ 100mm
    • Density of the wall
      ≤ 650kg per m3
    • Aggregate length of any additional wall per m2 of the roof area
      ≤ 0.3m
  3. Not used as a protective barrier
  4. Thickness of the roof slab supporting the structure
    ≥ 150mm
  5. No additional load to any cantilevered slab
  6. Not involving alteration to any other structural elements

3.56

  1. Height of the structure, including any feature at its top
    ≤ 1.5m
  2. If the lower part of the structure is a solid fence wall,
    • Height of the wall alone
      ≤ 300mm
    • Thickness of the wall
      ≤ 100mm
    • Density of the wall
      ≤ 650kg per m3
    • Aggregate length of any additional wall per m2 of the roof area
      ≤ 0.3m
  3. Not used as a protective barrier
  4. Thickness of the roof slab supporting the structure
    ≥ 150mm
  5. No additional load to any cantilevered slab
  6. Not involving alteration to any other structural elements

External mesh fence or metal railing on top of a solid fence wall on-grade

The prescribed building or building works item

10

The prescribed building or building works items 10

Corresponding minor works item

1.59

  1. Not located on an unauthorised solid fence wall
  2. The aggregate height of the wall and the fence or railing, including any feature at its top
    ≤ 10m
  3. Height of the solid fence wall
    ≤ 2.5m
The prescribed building or building works item

11

The prescribed building or building works items 11

Corresponding minor works item

2.57

  1. Not located on an unauthorised solid fence wall and a solid fence wall falling within the description of Designated Exempted Works item 5 that was erected, altered or repaired without the approval and consent of the Building Authority
  2. The aggregate height of the wall and the fence or railing, including any feature at its top
    ≤ 5m
  3. Height of the solid fence wall
    ≤ 2.5m
  4. Not used as a protective barrier
Top