Minor amenity features eligible for validation

Trellis

The technical specifications of the trellis for validation and corresponding minor works items are listed in Part 4 of Schedule 3 of the Building (Minor Works) Regulation (B(MW)R). The works must be in existence or completed before 1 September 2020.

Trellis in a garden on-grade

The prescribed building or building works item

18

The prescribed building or building works items 18

Corresponding minor works item

2.44

  1. Height of the trellis
    ≤ 2.5m
  2. If located in a private garden,
    • Aggregate of the area covered by each trellis located in the garden
      ≤ 20m2 and ≤ 5% of the total area of the garden
  3. If located in a non-private garden,
    • Each trellis covers an area ≤ 20m2; and
    • Aggregate of the area covered by each trellis
      ≤ 10% of the total area of the garden
  4. Length and width of every opening of the overhead frame of the trellis are respectively
    ≥ 200mm
  5. Horizontal clearance of the trellis from any other structure
    ≥ 500mm

Trellis on a roof of a building

The prescribed building or building works item

19

The prescribed building or building works items 19

Corresponding minor works items

1.45

  1. Height of the trellis
    ≤ 2.5m
  2. If located in a common part of the building,
    • Each trellis located in that common part covers an area
      ≤ 20m2; and
    • Aggregate of the area covered by each trellis
      ≤ 5% of the total area of that part
  3. If located in a part that is not a common part of the building (non-common part),
    • Aggregate of the area covered by each trellis
      ≤ 20m2 and ≤ 5% of the total area of that part
  4. No additional load to any cantilevered slab
  5. No alteration to any other structural elements
  6. Length and width of every opening of the overhead frame of the trellis are respectively
    ≥ 200mm
  7. Horizontal clearance of the trellis from any other structure
    ≥ 500mm

2.45

  1. Height of the trellis
    ≤ 2.5m
  2. If located in a common part of the building,
    • Each trellis located in that common part covers an area
      ≤ 5m2; and
    • Aggregate of the area covered by each trellis located in that common part
      ≤ 5% of the total area of that part
  3. If located in a part that is not a common part of the building (non-common part),
    • Aggregate of the area covered by each trellis
      ≤ 20m2 and ≤ 5% of the total area of that part; and
    • Each trellis located in that non-common part covers an area
      ≤ 5m2
  4. No additional load to any cantilevered slab
  5. No alteration to any other structural elements
  6. Length and width of every opening of the overhead frame of the trellis are respectively
    ≥ 200mm
  7. Horizontal clearance of the trellis from any other structure
    ≥ 500mm