Skip to Content

Minor amenity features eligible for validation

Supporting structure or metal casing for a building services installation(1)

The technical specifications of the supporting structure or metal casing for a building services installation for validation and corresponding minor works items are listed in Part 4 of Schedule 3 of the Building (Minor Works) Regulation (B(MW)R). The works must be in existence or completed before 1 September 2020.

The prescribed building or building works item

1

The prescribed building or building works items 1

Corresponding minor works item

1.50

  1. The supporting structure or casing is located on-grade, on a canopy (other than a cantilevered slab) or on a roof (other than a cantilevered slab) of a building
  2. Not involving alteration to any other structural elements
  3. For a supporting structure:
    • Height of the supporting structure
      • for an antenna or transceiver
        ≤ 2.5m
      • for any other BSI
        ≤ 1.5m
  4. For a casing:
    • Weight
      ≤ 10% of the weight of the BSI
    • The inner surface of the casing and the BSI
      ≤ 200mm apart in all directions
The prescribed building or building works item

2

The prescribed building or building works items 2

Corresponding minor works item

3.50

  1. The supporting structure or casing is located on-grade or on a roof (other than a cantilevered slab and an inaccessible roof) of a building
  2. Not involving alteration to any other structural elements
  3. For a supporting structure:
    • Weight BSI
      • ≤ 200kg; and
      • Average weight of BSI ≤ 100kg/m2 of the ground area (if located on–grade) or slab area (if located on a roof)
    • Height of the supporting structure
      • for an antenna or transceiver
        ≤ 2.5m
      • for any other BSI
        ≤ 1.5m
  4. For a casing:
    • Weight
      ≤ 10% of the weight of the BSI
    • The inner surface of the casing and the BSI
      ≤ 200mm apart in all directions
Notes:
  1. Building services installation (BSI) includes (i) any solar water heating system, photovoltaic system, antenna, transceiver, air-conditioning unit, water cooling tower, light fitting and pump set (installations); and (ii) any duct associated with any of the installations; and excludes any water tank, lift, stairlift, lifting platform, ventilation duct and radio base station.
Top