Minor works items - 3.54
- Jump to
- Item details
- Submission procedure
Item details
| Item no. | 3.54 |
|---|---|
| Item class/type | Class III TypeA |
| Nature of works | Erection/Alteration |
| Location of the external pole | Located on a roof of a building |
| Result in any additional load to any cantilevered slab | No |
| The works involve the alteration of any other structural elements | No |
| The height of the pole, including any feature at the top | Not more than 1.5m |
| The weight of the pole, including any feature at the top but excluding any pedestal | Not more than 100kg |
| If there is more than 1 pole on the roof, the distance between the poles | At least 2.5m away from each other |
| The thickness of the roof slab supporting the pole | Not less than 150mm |
| Other requirement | Not involve Designated Exempted Works item 19 |
More details: See Item 3.54 Description of building works, Schedule 1 - Part 3 - Division 3, Building (Minor Works) Regulation
Submission procedure
Step 1
Owner or their agent
Appoint and Prescribed Registered Contractor (Class III of Type A)
Step 2
Prescribed Registered Contractors
Submit MW05 - Notice of Commencement, documents, photos within 14 days after completion of work